Download as a PDF
Download as a Word Document
        
    
        
            
        
        
            PART 1 - GENERAL
        
    
        
            
        
        
            1.1 SUMMARY
        
    
        
        
            - Section includes: StonePly toilet compartments, urinal screens, privacy screens, including required fittings, hardware, and accessories.
 - Furnish and install supplementary blocking and accessories as shown in drawings for a complete and secure installation.
 
        
    
        
            
        
        
            1.2 REFERENCES
        
    
        
        
            - Americans with Disabilities (ADA) Standards for Accessible Design.
 - ANSI A117.1 - American National Standard for Buildings and Facilities - Providing Accessibility and Usability for Physically Handicapped People.
 - ASTM E84 - Surface Burning Characteristics of Building Materials.
 - UFAS - Uniform Federal Accessibility Standards.
 - ASTM C 119-04: Terminology Relating to Dimension Stone
 
        
    
        
            
        
        
            1.3 SUBMITTALS
        
    
        
        
            - Product Data: Submit product data, specifications and manufacturer’s installation instructions.
 - Shop Drawings: Submit shop drawings for architect’s review and approval prior to fabrication, including pertinent details for installation, showing layout plan, sizes, attachments, supports and adaptation of system to specific project.
 - Samples: Submit a minimum of one 6" by 6" sample for each stone type selected.
 - Test Data: Submit a summary of testing conducted verifying partition panel performance characteristics.
 
        
    
        
            
        
        
            1.4 QUALITY ASSURANCE
        
    
        
        
            - Source: Provide StonePly partitions which are the products of one manufacturer.
 
        
    
        
            
        
        
            1.5 FIELD MEASUREMENTS
        
    
        
        
            - Installer shall verify that field measurements are as indicated on shop drawings. Advise of any changes before fabrication and indicate measurements on Shop Drawings.
 - Coordination: Coordinate location and quantity of any concealed in wall blocking.
 
        
    
        
            
        
        
            1.6 DELIVERY, STORAGE AND HANDLING
        
    
        
        
            - Deliver materials and products in unopened factory labeled packages.
 - Store products in manufacturer's unopened packaging until ready for installation, in a clean dry area protected from weather, moisture and damage; store units upright and not stacked unless permitted by manufacturer.
 
        
    
        
            
        
        
            PART 2 - PRODUCTS
        
    
        
            
        
        
            2.1 ACCEPTABLE MANUFACTURER
        
    
        
        
            Acceptable Manufacturer:
StonePly Co.
4400 Oneal St
Greenville, TX  75401
Tel: (903) 454-0904 Fax: (903) 454-3642
Email: sales@stoneply.com   www.stoneply.com
Substitutions:  Not permitted.
        
    
        
            
        
        
            2.2 MATERIALS AND PRODUCTS
        
    
        
        
            Varieties and Source:
- Stone: [Insert stone variety] by StonePly Co.
 
The stone shall match the sample
- Stone Finish shall be (select one) [polished], [honed],or [custom], [to match the approved sample].Polished finish is standard.
 
All reinforced stone partition panels and doors shall have the following properties.
- Thickness 1” or 1¼” to match standard of design
 
- Facing: ¼” thickness of natural granite, marble or limestone as selected
 - All exposed edges of panel shall be natural stone
 - Reinforcing: ½” or ¾“aluminum honeycomb composite bonded with high strength epoxy.
 - Average Weight: 4.5 lbs. per sq. ft.
 - Dimensional Tolerance: Plus or minus 1/8" (3.2mm) in all directions. Plus or minus 1/8" (3.2mm) diagonally.
 
        
    
        
            
        
        
            2.3  PERFORMANCE REQUIREMENTS
        
    
        
        
            - The stone panel’s performance shall meet or exceed the following properties.
 - Acid-Freeze-Thaw: Loss in flexural strength shall not exceed 20% after 100 freeze thaw cycles + 170F to -10F immersed in dilute sulfuric acid.
 - Large Missile Impact test: Missile impact panel with a solid wood stud, nominal 2 x 4, #2 surface dry, Southern Pine of not less than 8'-6'. in length and 9 lbs. in weight at a velocity between 50 and 52 ft./sec. without defined specimen failure.
 - Tension Bond Capacity: Shall exceed the tensile strength of the stone selected or 320 psi following accelerated aging by rapid freeze thaw temperature cycling from -20 degrees F to +130 degrees F.
 - Flame Spread ASTM E-84 : 0 Maximum smoke development: 5. Maximum fuel contribution: 0
 
        
    
        
            
        
        
            2.4  ACCESSORIES
        
    
        
        
            Brackets: Stirrup Type: U-brackets,
- [Chrome-plated, nonferrous, cast zinc alloy]
 - [Clear anodized aluminum]
 - [Stainless steel]
 - [Chrome-plated brass].
 
Hardware and Accessories: Manufacturer's standard design hardware and accessories.
- [Chrome-plated, nonferrous, cast zinc alloy]
 - [Clear anodized aluminum]
 - [Stainless steel]
 - [Chrome-plated brass].
 
Fasteners: Manufacturer's exposed fasteners of stainless steel or chrome-plated steel or brass, finished to match hardware.
- Provide theft-resistant-type heads.
 
- Provide through-bolt applications.
 
        
    
        
            
        
        
            2.5 DOORS
        
    
        
        
            - Provide 24-inch- wide in-swinging StonePly doors for standard toilet compartments
 - Provide 36-inch- wide out-swinging StonePly doors with a minimum 32-inch- wide clear opening for toilet compartments indicated to be ADA accessible.
 - Hardware:
- Hinges: Self-closing type, adjustable to hold doors open at angle up to 90 degrees.
 - Latch and Keeper: Latch unit designed for emergency access with door strike and keeper.
 - Coat Hook: Combination hook and rubber-tipped bumper, sized to prevent door from hitting compartment-mounted accessories.
 - Door Bumper: Rubber-tipped bumper at out-swinging doors.
 - Door Pull: Door pulls complying with accessibility requirements at out-swinging doors. Provide units on both sides of doors at accessible compartments.
 
 
        
    
        
            
        
        
            PART 3 – EXECUTION
        
    
        
            
        
        
            3.1 PREPARATION
        
    
        
        
            - Verify that site conditions are ready to receive work and opening dimensions are as indicated on shop drawings.
 - Verify correct spacing of plumbing fixtures.
 
        
    
        
            
        
        
            3.2 INSTALLATION
        
    
        
        
            - Install in accordance with applicable code and manufacturer's recommendations, secure, plumb and true to line.
 - Attach panels and pilasters to brackets with tamper-resistant thru-bolted screws.
 - All panels shall be installed in proper alignment in accordance with the approved Shop Drawings.
 
        
    
        
            
        
        
            3.3 ADJUSTMENT
        
    
        
        
            - Adjust doors to work smoothly and correctly.
 - Adjust and align hardware to uniform clearance at vertical edge of doors.
 - Adjust hinges to locate in swing doors in partial open position and out swing doors in closed position when unlatched.
 
        
    
        
            
        
        
            3.4  CLEANING
        
    
        
        
            - Clean all dirt and marks from stone partition panels using water or a stone cleaner appropriate for the type of stone and per manufacturer’s recommendations.